However the typical temperature settings are as follows.
Furnace high limit switch reset.
Another common type is the solid state high limit switch which is smaller a circular in design.
Locate your furnace s heating duct.
If the high limit switch is tripped by overheating several times in a row then the furnace will go into lockout mode where it will not turn back on at all until it s serviced and reset.
The limit switch shuts off the burner when the temperature exceeds a preset temperature.
It is best to consult the manual for your furnace if you want to reset the limit switch.
There is a difference between a limit switch and a rollout switch.
One common symptom of a failing or blocked heat exchanger is the roll out switch tripping.
The blower will continue to run until either the system is reset or the limit switch closes.
Then turn on the power and let the furnace restart.
Repair experts tell us that they often show up at a residence only to find that the unit isn t getting power because of a tripped breaker or a flipped switch.
These also should be tested with a multi meter for continuity.
Remove the furnace access panel to get to the internal components.
Locate the white limit switch.
How to reset the limit switch on a goodman furnace step 1.
The solid state switches sometimes have a reset button that should be checked for before replacing.
When the temperature reduces to normal the burner will come back on.
The instructions differ depending on whether you have a combination switch or separate high and fan control limit switches as well as on the specific model you have.
Look at each.
So check that first.
Depending on your furnace model the.
I believe high limit switches are normally closed and they should always fail open.
Heating ducts are typically located in a home s basement or utility closet.
When the high limit switch trips the flame heating element will be shut off and the blower will continue to run to clear the heat.
Flip the furnace power switch to off and wait for at least five minutes.
It will be located at the top of the panel.
The limit switch is a safety switch that monitors t.
In this episode of repair and replace vance shows how to replace the high limit switch in a gas furnace.
This happens because the flames are not being drawn into and throu.
Flip the circuit breaker switch that corresponds to the goodman furnace to the off position to disrupt the.
Limit switches turn off the burner and turn on the circulating fan if there is a high temperature condition in the furnace.